How to Test Kaivac 17501 Batteries and ARMOR Communication

Modified on Mon, 29 Apr at 9:39 AM

How to mount, charge and test Batteries


How to test Vacuum and Pump motors

  1. Following the reference picture below
    1. Power on the Vacuum motor (switch 4 on top left)
      1. Run for 2 minutes 
      2. Power off the vacuum motor
    2. Power on the Pump motor (switch 2 on top right) 
      1. Run for 1 minute 
      2. Power off pump motor



Verification of ARMOR device communication

  1. Wait 10-12 minutes after running Vacuum and Pump tests above. 
    1. Browse to https://check.armordata.io 
    2. Select your device by: 
      1. Enter your Asset Serial number 
        1. Serial number is located on the outside of the unit near the battery (easier to see with battery removed).
      2. Check nearby 
        1. This will show a list of assets near you. Drop down the list and choose the serial number of the unit you are testing. 
        2. The next page should show you a RunTime event in “green” with a value ~3 minutes
          1. This page can be viewed while running the test multiple times if needed 

Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article